LEGION Model Builder Help

Creating a single stair (Filter)

To create a single stair (Filter):

  1. Follow steps 1 to 5 in Creating a single stair (Target) .

    You are prompted to "Create as Target or Filtering object? [F]/T".

  2. Filtering is the default choice, so just press Enter to create the Stair as a filter object.

    The Edit Stair dialog is displayed.

  3. Enter a meaningful name for the new stair in the 'Name' box.
  4. Select an 'Entity direction on stair':
    • Up only
    • Down only
    • Bidirectional (default option)
  5. If you want to change the default 'Distance Factors', enter new values in the boxes labelled:
    • Distance Factor Up
    • Distance Factor Down

    For more information on these factors, see "Distance Factors for Stairs and Escalators" in Linking to Escalators .

  6. In the box labelled 'Link Properties', decide what Entities will do when leaving the Stair:
    • Do not change target – Entities keep same target
    • Revert to final destination – Entities proceed to their Final Destination
    • Specify links – add specific links using the available 'Links from Top' and 'Links from Bottom' tabs and by following Linking methods
  7. If you need to test your model against required regulatory flow rates you may wish to set a maximum value for 'Flow Rate Limiting'. To do so, check the box Maximum and enter a value for people/minute in the adjacent field.
  8. Set the Stair's filter settings by clicking on 'Up Filter', 'Down Filter' (or both if it's a bidirectional Stair) and following the steps outlined in Specifying filter settings .
  9. To set Availability and possibly Condition parameters, follow the steps in Setting Availability parameters .
  10. Click OK to close the ‘Edit Stair’ dialog box.